OL 410-1000 Precision Lamp Source (1000W)

The OL 410 is a microprocessor-controlled, precision DC lamp source specifically designed to accurately operate tungsten filament lamp standards and calibration sources. The power output range is 1000 watts for the OL 410-1000.

The OL 410-1000 is for use with OL Series 200 and OL FEL Standards.

GET A QUOTE
SKU: OL 410-1000 Category:

Description

The OL 410 is a microprocessor-controlled, precision DC lamp source specifically designed to accurately operate tungsten filament lamp standards and calibration sources. The power output range is 1000 watts for the OL 410-1000.

Tungsten lamp standards must be operated at their specified calibration current in order to realize the accuracy of the standard. A small error in setting the lamp current can induce a sizeable, wavelength dependent error in the spectral output of the lamp. The OL 410 enables the lamp current to be set to an accuracy of better than ±0.02%, a factor of about 121⁄2 better than most other commercial power supplies, which are typically 0.25%.

In order to eliminate electrical shocking of the lamp due to high initial current surges, a ramp function is used to control the turn-on current rise. Once the instrument is turned on, the current automatically increases at a slow, safe rate until the set current is reached. A fail-safe, shut down circuit protects the lamp standard against any equipment malfunctions.

1000 Watts

120 Volts DC

8.4 Amps DC

3.00

0.001

0.02%

10ppm

< 2 ppm/ V

< 25 ppm/°C

100/ 115/ 200/ 230 VAC, 50/ 60 Hz <br> ** The power input voltage is factory configured on the OL 410-1000

20 / 20 / 10 / 10 A

15°C to 35°C

10% to 85% <em>(Non-condensing)</em>

14.62" D x 17.00" W x 7.00" H

37.1 cm D x 43.2 cm W x 17.8 cm H

47.0 lbs <em>(21.3 kg)</em>

Twist-lock Latch Design Connector

Bulletin

OL 410 Precision Lamp Source

OL 200IR 1000-W Irradiance Standard (250 – 4500 nm)

The OL 200IR is a 1000-W DXW irradiance standard lamp. These lamps have tungsten coiled-coil filaments enclosed in a...

OL FEL-B Irradiance Standard (750 – 2500 nm)

Optronic Laboratories offers a 1000-W FEL-B Irradiance Standard. The spectral irradiance calibration of this lamp covers the 750-2500 nm...

OL FEL-P (Photometric)

Optronic Laboratories offers an OL FEL-P Irradiance Standard, which has a Photometric calibration. The spectral irradiance calibration of this...

OL 200D 1000-W Irradiance Standard (Total Irradiance)

The OL 200D is a 1000-W DXW Total Irradiance standard lamp. These lamps have tungsten coiled-coil filaments enclosed in...

OL 200M 1000-W Irradiance Standard (250 – 1100 nm)

The OL 200M is a 1000-W DXW Irradiance Standard lamp. These lamps have tungsten coiled-coil filaments enclosed in a...

OL FEL-D Irradiance Standard (Total Irradiance)

Optronic Laboratories offers an OL FEL-D Irradiance Standard, which is calibrated for Total Irradiance. The OL FEL-D uses the

OL 200B 1000-W Irradiance Standard (750 – 2500 nm)

The OL 200B is a 1000-W DXW irradiance standard lamp. These lamps have tungsten coiled-coil filaments enclosed in a...

OL 200A 1000-W Irradiance Standard (250 – 750 nm)

The OL 200A is a 1000-W DXW irradiance standard lamp. These lamps have tungsten coiled-coil filaments enclosed in a...

OL FEL-IR Irradiance Standard (250 – 4500 nm)

Optronic Laboratories offers a 1000-W FEL-IR Irradiance Standard. The spectral irradiance calibration of this lamp covers the 250-4500 nm...

OL 200V 1000-W Irradiance Standard (380 – 780 nm)

The OL 200V is a 1000-W DXW irradiance standard lamp. These lamps have tungsten coiled-coil filaments enclosed in a...

1 YEAR STANDARD WARRANTY

Optronic Laboratories warrants that the equipment has been carefully tested, inspected and left the Factory in proper working condition, free of visible defects.  Optronic Laboratories warrants the equipment to be free from defects in material and workmanship, under normal use and operation, for a period of one (1) year after the date of initial operation, or demonstration; or eighteen (18) months from the date of shipment from the Factory; or whichever occurs first. The warranty is limited to the free replacement of all-defective parts and free labor during the first year of warranty.  Defective parts replaced under this warranty shall become the property of Optronic Laboratories. The above stated Warranty is subject to the following conditions: Equipment being installed within the United States of America, Canada, or sold by authorized Optronic Laboratories representatives or their agents outside the continental United States. The equipment being installed is operated and maintained in accordance with Optronic Laboratories’ operating instructions, maintenance instructions and specifications. Utilization of only Optronic Laboratories’ authorized parts and components.  The utilization of a duly authorized representative for all work performed on Optronic Laboratories equipment during the warranty period.  Any variation(s) to the above warranty must be in writing and mutually acceptable by Optronic Laboratories and the customer. The warranty shall not apply to damages resulting from errors in installation, nor shall it apply to any equipment, which has been subject to damages, alterations or misuse by the purchaser.  Parts of the equipment, which would be generally considered as expendable service items during normal use, such as fuses, lamps, detector shields, etc., are not covered under the warranty. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THIS DESCRIPTION, AND EXPRESSLY NO IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL Optronic Laboratories BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR ANTICIPATED LOSS OF PROFITS SUFFERED BY THE PURCHASER. Extended Warranty Plans are also available.